THR02 Alternative Replace to CFC-12 and HFC-134a |
1.Environmental Characters of THR02
You can find from the charts that the ODP of THR02 is zero. GWP of it is 1/25 of HFC-134a.
VOC of it is 1/100 of R600. Its composite environmental targets are the best. It is a new
altermative replace to HFC-134a.
REFRIGERANT |
ODP |
GWP |
VOC |
CFC-12 |
0.9 |
8500 |
0.1 |
HFC-134a |
0 |
1300 |
0.6 |
R600a |
0 |
3 |
320 |
THR02 |
0 |
50 |
1 |
2.Safe Characters of it
it is non toxicity owing to a physical mixture of three non toxicity matter. It is
nonflammable after test and calculation.
3.Themal Performance of it
The charts mentioned above show thermal perfomance contrast of it and CFC-134a R600a
under refrigerator and automobile A/C Terms greating.
|
|
(a)REFRIGERATOR |
(b)AUTOMBILE AIR-CONDITIONING |
(a)REFRIGERATOR
REFRIGERANT |
CDP |
CAOASUTY |
CFC-12 |
1.00 |
1.00 |
HFC-134a |
0.98 |
0.93 |
R600a |
1.01 |
0.509 |
THR02 |
1.02 |
0.98 |
(b)AUTOMBILE AIR-CONDITIONING
REFRIGERANT |
CDP |
CAOASUTY |
CFC-12 |
1.00 |
1.00 |
HFC-134a |
0.95 |
0.97 |
THR02 |
1.03 |
0.99 |
From the charts of the it, can save energy, its Cop is higher than CFC-12, HFC-134a and
hydroCarbon R600a, and no need to change the compressor of former system.
China Household Electric Appliance Research Institute, Beijing Embrace Snowflake
Compressor Co. and Thermodynamics Lab of Tsinghua University, all made a series and aging
tests for the refrigerator used THR02, proved that all indexes were up to national
standard, the change of its parameter is very little, proved the thermal performance of
refrigerator are steady. Rongsheng Refrigerator Co., get good result by test for amount of
it refrigerator.
THR02 can be used directly in refrigerator and automobile air-conditioning to replace to
HFC-134a needs high technique in use and has higher GWP value.
4.Drop-in Effect
Castrol International Co. tested the miscibility of it and different kinds of oil,
proved that it is miscible with mineral oil of CFC-12 system, THR02 and material of
CFC-12 and HFC-134a system were compatible too after the examination of material
compatibility according to the inernational standard.
The THR02 can be drop-in, no need to change the major parts of former system and the
production line.
|